LT-260顶部安装沉浸式液位变送器TOP MOUNTING IMMERSION LEVEL TRANSMITTER
LT-260 |
|
|
RANGE | |
: |
-1/0/50 mmHO ~ 5 kg/cm² |
|
|
SENSOR | |
: |
CERAMIC SENSOR WITH FLANGE MOUNTING |
|
|
OUTPUT | |
: |
4 - 20mA WITH ZERO & SPAN ADJUSTABLE |
|
|
PROTECTION | |
: |
Exd IIC T6 |
Nominal span: The pressure interval between the minimum and maximum values of the sensor nominal range. The span is a number. Measuring range: The pressure range between minimum and maximum for which the transmitter has been calibrated. Measuring span: The pressure interval between minimum and maximum values of the measuring range. Input scale initial value or zero input: Minimum pressure value included in the measuring range. Input full scale value: Maximum pressure value included in the measuring range. 1) Transmitter Parameters. The parameters that are available for display and setting Measuring Span: Possibility to change by 0.05% steps from 120% to 7% of the nominal span. (see table). Zero Adjustment: By 0.1% steps from -9.9% to +9.9% of measuring span Span Adjustment: By 0.1% steps from -9.9% to +9.9% of measuring span Suppression/Elevation: By 0.05% steps of nominal span from 0 to 100% for elevation and from 0 to 93% for suppression Damping : Adjustable by 1 sec steps from 0 to 15 sec. Reverse Output and square root extraction : Selectable via software. Measuring Units : For the measuring span display, one of the following units may be selected: mbar, bar, kPa, MPa, mmH20, mH2O, ㎏ /㎠ , mmHg. GENERAL The transmitter LT-260 measures levels of liquids in open tanks at atmospheric pressure. The LT-260 comprises two main element : the immersion pressure sensor and the electronic module connected by a cable of variable length. The sensor generates a signal corresponding to the hydrostatic pressure and it is complete with a PTC thermistor which also transmits the temperature of the measuring cell to the electronic system. On the basis of these two values and of the configuration parameters the electronic system generates a standard output signal (4 to 20mA, two wires system) and displays all the necessary data on the LCD display. The operating parameters can be changed by means of the four pushbuttons that are below the LCD display. Among the relevant characteristics of this microprocessor based transmitter, are the following: -wide rangeability for the measuring span (abt. 1 to 17) -automatic temperature compensation in the measuring cell FUNCTIONAL DATA With reference to the following, please note these definitions: Nominal range:(Referred to the sensor mounted on the instrument) the pressure range (included between a minimum and a maximum values) to measure which the sensor has been designed. REF. NOM. RANGE mH2O SPAN min.(mH2O)max OVERPRESS. bar N 0 / 1.6 0.112 - 1.92 10 P 0 / 4 0.28 - 4.8 10 Q 0 / 10 0.7 - 11 30 R 0 / 25 1.75 - 26 30 S 0 / 60 4.2 - 61 30 T 0 / 160 11.2 - 161 100 U 0 / 400 28 - 401 100
PHYSICAL CHARACTERISTICS. Power supply : 12.35-30 Vdc with no load Supply voltage to permissible load relation: 0/250 Ohm for 17.35 Vdc 0/582.5 Ohm for 24 Vdc 0/882.5 Ohm for 30 Vdc Output signal ; 4 -20mA, 2 wiresl Overpressure limits :See table Settling time : 150ms (at 27 ℃ ) Connecting cable - Insulating : 5000 V a.c. - Voltage test : conductor / conductor 1500 V a.c. per min., conductor/shield 1000 V a.c. per min. - Capacity : conductor / conductor 50 ;F/m; conductor / shield 90 pF/M. - Inductance : 1mH/km. - L/R loop rate : ≤10μH/Ω 3) OPERATING AND CONDITIONS Temperature Process fluid : -20 ~ + 80℃ Housing : -20 ~ + 80℃ Transportation and storage : -20 ~ + 90℃ Relative Humidity : 0 ~ 100% LCD display reading : -10 ~ + 65℃ Performance Unless otherwise stated performance specifications are referred at atmospheric pressure, nominal span, silicone oil filling and are given as a percent of span. Accuracy rating: It is assured within the following limits: Non linearity : Resettable with 0.1% accuracy. Repeatability : = 0.10% Hysteresis : = 0.10% Dead band : negligible Operating Influences Thermal drift: It is referred to -10 ~ + 65℃ range. Zero: 0.1%/10℃ . Span: 0.1%/10℃ at nominal range. Power supply effect : Negligible between 12.35 and 30 V d.c. Intelligent Transmitters GT-438 12 - 99 4) PHYSICAL SPECIFICATIONS Materials SENSOR Diaphragm : Hastelloy C or ceramic, SUS 316L. Other wetted parts : SUS 316. Hastelloy - C, SUS 316 + PTFE, Other special. Gaskets : P.T.F.E Bolts : SUS 316. Filling fluid : Silicon oil (No use for ceramic) CABLE Acrylic insulated - conductors and shield in copper- reference tubing in PTFE. Connectors : Aluminium processed and passivated-MILC26482 ELECTRONIC MODULE Housing : Die cast aluminum alloy AL UNI 4514 finished with epoxy resin (RAL 5014). Nameplate : Stainless steel, fixed on housing. Flange mounting: SUS 316 or PVC flange Identification tag : S.S. Environmental protection: The transmitter is dust and sand tight and protected against sea waves effects as defined by IEC IP 66 - Suitable for tropical climate operation as defined in DIN 50.015. Electrical connections : Two cable entries on electronic for output signal( up to 1.5㎟. 14 AWG) Earth connections for shield of cable. 5) EXPLOSION PROTECTION Classification Type: Intrinsic safety Ex ia IIC, T6, T5, T4 Max Amb. temp.: 40℃ for T6, 55℃ for T5, 80℃ for T4 Condition A No-load voltage: = 30 V d.c. Short circuit current: = 120 mA. Max transferred power: 0.75 W. Condition B No-load voltage: = 25.2 V d.c. Short circuit current: = 152 mA. Max transferred power: 0.95 W.
|