SCR-300B SCR-400B SCR-600B SCR-800B SCR-1000B SCR-1500B直流接触器继电器
Type : SCR-□ B Type
▷ Most suitable for Battery Charge Circuit : Pick Up 60% ~ rated Voltage
▷ Auxiliary Contact attachment: According to customer’s order
▷ Magnetic Blowout (DC 90V)
▷ Coil can be continuously used.
▷ Mounting Bracket: Easy Installation
▷ Suppresses Coil Surge: Diode can suppress the Surge created when Coil OFF
▷ High Contact Capacity
▷ Magnetic Latch Type available → One shot Pulse: Coil On,
Power Loss of Coil is unnecessary due to the ON state of Main Contact by the Magnetic Latch → One Shot Negate Pulse : Coil On
However, Main Contact is still in ON position even though Power is OFF, so please be careful in handling
Standard, Change-over type
Type |
SCR-300B |
SCR-400B |
SCR-600B(E) |
SCR-800B |
SCR-1000B(E) |
SCR-1500B(E) |
Rated Current(A) |
300A(260A) |
400A |
600A |
800A |
1000A |
1500A |
Rated Voltage(V) |
DC 60V |
Voltage Drop between contacts(mV) |
15mV at 100A |
Operating Voltage(V) |
DC 12V, 24v, 30V, 48V, 60V |
Pull-in Voltage(V) |
Under 75% of Operating Voltage |
Drop-out Voltage(V) |
Under 10% of Operating Voltage |
Power Consumption(W) |
5 ~ 7 |
Aux. Contact |
4A at DC 24V, 1A at DC 60V, 0.5A at DC 125V | Magnetically Latching
Type |
SCR-300B |
SCR-400B |
SCR-600B(E) |
SCR-800B |
SCR-1000B(E) |
SCR-1500B(E) |
Rated Current(A) |
300A(260A) |
400A |
600A |
800A |
1000A |
1500A |
Rated Voltage(V) |
DC 60V |
Voltage Drop between contacts(mV) |
15mV at 100A |
Operating Voltage(V) |
DC 12V, 24v, 30V, 48V, 60V |
Pull-in Voltage(V) |
Under 75% of Operating Voltage |
Drop-out Voltage(V) |
Under 10% of Operating Voltage |
Power Consumption(W) |
5 ~ 7 |
Aux. Contact |
4A at DC 24V, 1A at DC 60V, 0.5A at DC 125V |
Type : SCR-□ A Type
▷ Most suitable for Battery Charge Circuit : Pick Up 60% ~ rated Voltage
▷ Auxiliary Contact attachment: According to customer’s order
▷ Magnetic Blowout (DC 90V)
▷ Coil can be continuously used
▷ Mounting Bracket: Easy Installation
▷ Suppresses Coil Surge: Diode can suppress the Surge created when Coil OFF
▷ High Contact Capacity
▷ Magnetic Latch Type available → One shot Pulse: Coil On
Power Loss of Coil is unnecessary due to the ON state of Main Contact by the Magnetic Latch → One Shot Negate Pulse : Coil On
However, Main Contact is still in ON position even though Power is OFF, so please be careful in handling
|
제품사양 |
Classification |
Item |
Specification |
Contact section |
Rated Current |
DC 30V 30A, AC 277V 30A |
Voltage Drop |
30mV at 30A |
Dielectric Voltage |
COIL to frame |
There should be no insulation break if it is excited for one minute at 1500V.
|
COIL to contact |
Contact to frame |
Ambient Temperature |
- 50 ºC to + 55 ºC |
Coil section |
Operating Voltage(V) |
DC 12V, DC 24V, DC 48V |
Pull-in Voltage(V) |
Under 75% of rated voltage |
Drop-out Voltage(V) |
Under 10% of rated voltage |
Power Loss(A) |
Max 0.1A |
|